UFFOが運営するフードファイター小林尊の公式blogです。
takeru-kobayashi.com

« パーティー 開始10時 | メイン | »

farmer's market

05162011-1.jpg
またマーケット。

濃厚なヨーグルトを。

毎週末、フリーマーケットや直売市があるので楽しい。

リビングはアンティークの家具やランプ、絵を壁にかけたりと、温かい部屋になったけど、ベッドルームがまださみしい。

もうちょっとお気に入りを探して、寝る時もさらに気分よくいきたい。

リビングのソファで寝ちゃわないためにも。

コメント

Wow! Your article has quite a few readers. How did you get all of these bloggers to look at your post I'm jealous! I'm still getting to know all about blogs on the web. I'm going to view pages on your site to get a better idea how to attract more people. Thanks for the help!

I simply experienced your blog and loved it a great deal. I bookmarked it, continue the great function!

We are manufacturer and supplier of handbag display

Very nice template. Would you mind writing template name for your blog ? I searched on google "google reklam ajansi" and found myself here.Thanks..

Comparing Transformer-based and Transformerless Uninterruptible Power Supplies Industrial uninterruptible electrical power supplySelecting among transformer-based or transformerless uninterruptible energy supplies may not be an uncomplicated, specially previously mentioned 10kVA. The two technologies have their location in right now??s energy protection scenarios but the primary differences involving them are: animal dimensions, effectiveness, noise output and the amounts of input harmonious distortion that they carry forth Both uninterruptible strength offer styles produce a tightly regulated resource of uninterrupted strength nevertheless they differ in the way they create the dc voltage required by their inverters and their output phases Transformer-based Uninterruptible Strength Materials: until finally the early 1990s, the only style of on the net uninterruptible ability provide was transformer-based. Currently, the layout continues to be obtainable but generally in bigger sizes for UPS from 8 to 800kVA. Essentially the most ordinary applications for this are sufficient blue-collar sites This type of UPS has a robust transformer-isolated inverter output, which can make it extra suitable for the kind of application the place there may be a likelihood of electrical noise; spikes, transients, and most likely, a great degree of short-circuit currents The inverter generates an ac supply from its dc ability supply, and that is fed right into a step-up transformer. The primary operate of the transformer is always to increase the inverter ac voltage to that expected from the load. The transformer also protects the inverter from load disruption, while also giving Galvanic isolation (a procedure of isolating input and output) Modern-day inverter patterns use IGBTs (Insulated Gate Bipolar Transistors) in put of a lot more classic switching components (including power transistors and thyristors). IGBTs merge the fast-acting and great electric power capacity from the Bipolar Transistor using the voltage control functions of the MOSFET gate to kind a flexible, large frequency switching above device. This consequently has offered rise to a lot more muscular, businesslike and examined inverters Transformer-based UPS are also supplied that has a dual input choice as normal, which can be chosen at installation by simply just eliminating a linking connector from its input terminal. This permits it to become powered from two separate ac offer sources hence adding even more resilience. A transformerless UPS is often instaled with dual input capacity, with supplies deduced from your identical resource, but this really is ordinarily a factory-fit solution Transformerless Uninterruptible Ability Programs Transformerless UPS is a more recent pattern, frequently offered from 700VA to 120kVA. The primary reason behind the introduction of transformerless units was to scale back the general physical size and pounds so generating an uninterruptible strength supply unit additional ideal for more compact installations and/or pc room/office type environments, in which room may very well be limited. Additionally, it generates far a lot less noise and heat than its transformer-based cousin and has far reduced input harmonious distortion amounts making it congenial with environments where by digital products (much as pcs) may be extra alive to this type of distortion In location in the step-up transformer, a transformerless UPS works by using a staged practice of voltage conversion. The initial phase combines a rectifier and booster-converter to make a dc supply for that inverter. An anarchic, three-phase bridge rectifier converts the ac offer into a dc voltage. That is went via by a mid-point booster circuit to stage the dc voltage up to normally 700-800Vdc from which a battery charger and inverter are housed. In the second phase, the inverter requires the offer from the booster-converter and inverts it back to an ac voltage to provide the load An added benefit of this system is the fact that the rectifier can operate from possibly a 3 or single-phase input supply. This may be configured at installation for methods up to 20kVA. A control procedure makes certain a balanced, modulated dc voltage is offered towards the inverter in any respect instances as well as the inverter can run irregardless of UPS output load variations or mains electrical power offer fluctuations or disturbances Deciding on between Transformer-based or Transformerless Uninterruptible Electrical power Materials In numerous apps the preference amongst the two can be apparent. It is actually where by the two ranges co-occur, in terms of power rating, that the selection is much more perplexed. Consideration has to be provided then to: to begin with order price, animal size, running expenses, the set up natural environment, and in cautious, the amounts of input harmonious distortion they carry forth. Each styles might be operate in antiparallel to attain larger amounts of availability and resilience Over the last ten years, the gap concerning these two uninterruptible electric power offer technologies has lowered as makers have utilized prevalent methods and exploration & development efforts to equally patterns. The driving force behind this has been value and dimensions, alongside demands to better running effectiveness and cut down harmonious generation. Regarding on line performance, each styles render the exact same level of performance and are classed as VFI methods (voltage and frequency autonomous in accordance with EN/IEC 62040-3). Their principal differences are their effects on upstream materials along with the operating natural environment Transformerless UPS are frequently recognised as a lot more efficient and having a higher power factor than an equivalent transformer-based style and design, therefore operating costs is usually reduced Below 10kVA, the transformerless UPS layout dominates the on-line uninterruptible electric power provide market and has become the regular within data centre environments as they offer a more compact footprint, greater operating efficiencies and decrease sound output. However, the strengths on the transformer-based pattern come into play inside the blue-collar natural environment R K is the General Manager for Riello UPS Ltd the UK subsidiary of Riello UPS (RPS S.p.A) a leading European manufacturer of Uninterruptible Electrical power Materials and a co-author with the Ability Safety Guide

  • Taizhou huangyan yinhai electric tools CO,.LTD Our company is specialized in R&D and manufactures&sales of electric tools We developed electric hammer,electeic drills,stone cutting machine machine, electric pick, With German high-tech.products are more durable and affordable. Welcome to cooperate with us
  • http://www.yinhaitool.com
  • Oh, so unexpected, so surprise! Very touching, so well written and I have some perception, learning very much. Thank you for sharing. Very happy to see these and believe that your point of view. This same time,i love electric breaker very much !